Rietveld Code Review Tool
Help | Bug tracker | Discussion group | Source code

Unified Diff: installer/src/custom-action/close_application.cpp

Issue 5219280069066752: Issue #1186 - Change names that appear in the custom action (Closed)
Patch Set: Created Oct. 20, 2014, 1:42 a.m.
Use n/p to move between diff chunks; N/P to move between comments.
Jump to:
View side-by-side diff with in-line comments
Download patch
Index: installer/src/custom-action/close_application.cpp
===================================================================
--- a/installer/src/custom-action/close_application.cpp
+++ b/installer/src/custom-action/close_application.cpp
@@ -11,45 +11,45 @@
#include "interaction.h"
#include "custom-i18n.h"
-const wchar_t * ie_names[] = { L"IExplore.exe" } ;
-const wchar_t * engine_names[] = { L"AdblockPlusEngine.exe" } ;
+const wchar_t * browserNames[] = { L"IExplore.exe" } ;
+const wchar_t * engineNames[] = { L"AdblockPlusEngine.exe" } ;
//-------------------------------------------------------
//-------------------------------------------------------
-class IE_Closer
+class InternetExplorerCloser
{
- Process_Snapshot snapshot ;
+ ProcessSnapshot snapshot ;
- Process_Closer ie_closer ;
+ ProcessCloser browserCloser ;
- Process_Closer engine_closer ;
+ ProcessCloser engineCloser ;
public:
- IE_Closer()
- : snapshot(), ie_closer( snapshot, ie_names), engine_closer( snapshot, engine_names )
+ InternetExplorerCloser()
+ : snapshot(), browserCloser( snapshot, browserNames ), engineCloser( snapshot, engineNames )
{}
void refresh()
Eric 2015/01/04 19:02:43 Caught this one.
{
snapshot.refresh() ;
- ie_closer.refresh() ;
- engine_closer.refresh() ;
+ browserCloser.refresh() ;
+ engineCloser.refresh() ;
}
- bool is_running()
+ bool IsRunning()
{
- return ie_closer.is_running() || engine_closer.is_running() ;
+ return browserCloser.IsRunning() || engineCloser.IsRunning() ;
}
- bool shut_down()
+ bool shutDown()
Felix Dahlke 2014/10/22 16:00:33 Should be ShutDown(), hm?
Eric 2015/01/04 19:02:43 Changed all of them, including two calls below and
{
- if ( ie_closer.is_running() && ! ie_closer.shut_down() )
+ if ( browserCloser.IsRunning() && ! browserCloser.shutDown() )
{
// Assert IE is still running
// This is after we've tried to shut it down, so we fail
return false ;
}
- if ( engine_closer.is_running() && ! engine_closer.shut_down() )
+ if ( engineCloser.IsRunning() && ! engineCloser.shutDown() )
{
// Assert the engine is still running
// This is after IE has shut down itself and after we've tried to shut down the engine. Whatever.
@@ -61,7 +61,7 @@
//-------------------------------------------------------
-// abp_close_ie
+// AbpCloseIe
//-------------------------------------------------------
/**
* Exposed DLL entry point for custom action.
@@ -85,7 +85,7 @@
* In a silent installation, this is the only way getting a stance other than the default.
* In an interactive installation, AVOIDREBOOT skips the dialogs.
*
- * \param[in] session_handle
+ * \param[in] sessionHandle
* Windows installer session handle
*
* \return
@@ -107,34 +107,34 @@
* - MSDN [Custom Action Return Values](http://msdn.microsoft.com/en-us/library/aa368072%28v=vs.85%29.aspx)
*/
extern "C" UINT __stdcall
-abp_close_ie( MSIHANDLE session_handle )
+AbpCloseIe( MSIHANDLE sessionHandle )
{
// Utility typedef to shorten the class name.
- typedef Installer_Message_Box IMB ;
+ typedef InstallerMessageBox IMB ;
/*
- * Immediate_Session cannot throw, so it can go outside the try-block.
+ * ImmediateSession cannot throw, so it can go outside the try-block.
* It's needed in the catch-all block to write an error message to the log.
*/
- Immediate_Session session( session_handle, "abp_close_ie" ) ;
+ ImmediateSession session( sessionHandle, "AbpCloseIe" ) ;
// The body of an entry point function must have a catch-all.
try {
// MSI property BROWSERRUNNING is one of the return values of this function.
- Property browser_running( session, L"BROWSERRUNNING" ) ;
- Property browser_closed( session, L"BROWSERCLOSED" ) ;
+ Property browserRunning( session, L"BROWSERRUNNING" ) ;
+ Property browserClosed( session, L"BROWSERCLOSED" ) ;
- // Instantiation of Process_Closer takes a snapshot.
- IE_Closer iec ;
+ // Instantiation of ProcessCloser takes a snapshot.
+ InternetExplorerCloser iec ;
/*
* We take the short path through this function if neither IE nor engine is not running at the outset.
*/
- if ( ! iec.is_running() )
+ if ( ! iec.IsRunning() )
{
- browser_running = L"0" ; // The browser is not running.
- browser_closed = L"0" ; // We didn't close the browser (and we couldn't have).
+ browserRunning = L"0" ; // The browser is not running.
+ browserClosed = L"0" ; // We didn't close the browser (and we couldn't have).
session.log( "IE not running. No issue with reboot policy." ) ;
Eric 2015/01/04 19:02:43 Also this one.
return ERROR_SUCCESS ;
}
@@ -143,10 +143,10 @@
* As a (potentially) user-driven function, a state machine manages control flow.
* The states are organized around the policy stances.
*/
- enum Policy_State {
+ enum PolicyState {
// Non-terminal states
- not_known, // We don't know the user's stance at all
- part_known, // The user has indicated either ACTIVE or AUTOMATIC
+ notKnown, // We don't know the user's stance at all
+ partKnown, // The user has indicated either ACTIVE or AUTOMATIC
active, // Actively avoid reboot
automatic, // Automatically avoid reboot
// Terminal states
@@ -157,32 +157,32 @@
allow = success, // Allow reboot.
passive = abort, // Passively avoid reboot, that is, don't try to close IE.
};
- Policy_State state ;
+ PolicyState state ;
/*
* Use the AVOIDREBOOT property, if present, to set an initial state.
*/
- std::wstring avoid_reboot = Property( session, L"AVOIDREBOOT" ) ;
- std::transform( avoid_reboot.begin(), avoid_reboot.end(), avoid_reboot.begin(), ::towupper ) ;
- if ( avoid_reboot == L"" )
+ std::wstring avoidReboot = Property( session, L"AVOIDREBOOT" ) ;
+ std::transform( avoidReboot.begin(), avoidReboot.end(), avoidReboot.begin(), ::towupper ) ;
+ if ( avoidReboot == L"" )
{
- state = not_known ;
+ state = notKnown ;
}
- else if ( avoid_reboot == L"NO" )
+ else if ( avoidReboot == L"NO" )
{
state = allow ;
session.log( "Reboot allowed on command line." ) ;
}
- else if ( avoid_reboot == L"PASSIVE" )
+ else if ( avoidReboot == L"PASSIVE" )
{
state = passive ;
session.log( "Reboot avoided on command line." ) ;
}
- else if ( avoid_reboot == L"ACTIVE" )
+ else if ( avoidReboot == L"ACTIVE" )
{
state = active ;
}
- else if ( avoid_reboot == L"AUTOMATIC" )
+ else if ( avoidReboot == L"AUTOMATIC" )
{
state = automatic ;
}
@@ -209,13 +209,13 @@
if ( uilevel == L"5" || uilevel == L"4" )
{
interactive = true ;
- // Assert state is one of { not_known, allow, passive, active, automatic }
+ // Assert state is one of { notKnown, allow, passive, active, automatic }
}
else if ( uilevel == L"3" || uilevel == L"2" )
{
// Assert installer is running without user interaction.
interactive = false ;
- if ( state == not_known )
+ if ( state == notKnown )
{
// Assert AVOIDREBOOT was not specified
/*
@@ -238,38 +238,41 @@
/*
* Now that preliminaries are over, we set up the accessors for UI text.
- * We only use the object 'message_text' for interactive sessions, but it's cheap to set up and a hassle to conditionalize.
+ * We only use the object 'messageText' for interactive sessions, but it's cheap to set up and a hassle to conditionalize.
*
* The key "close_ie" is the component name within the file "close_ie.wxi" that defines rows in the localization table.
- * The identifiers for the message_text.text() function are defined within that file.
+ * The identifiers for the messageText.text() function are defined within that file.
*/
- Installation_Database db( session ) ;
- custom_message_text message_text( db, L"close_ie" ) ;
+ InstallationDatabase db( session ) ;
+ CustomMessageText messageText( db, L"close_ie" ) ;
/*
* State machine: Loop through non-terminal states.
*
- * Loop invariant: IE was running at last check, that is, iec.is_running() would return true.
+ * Loop invariant: IE was running at last check, that is, iec.IsRunning() would return true.
*/
while ( state <= automatic ) // "automatic" is the non-terminal state with the highest value
{
switch ( state )
{
- case not_known:
+ case notKnown:
/*
* Precondition: interactive session
*
* Ask the user "Would you like to close IE and avoid reboot?"
- * Yes -> Close IE somehow. Goto part_known.
+ * Yes -> Close IE somehow. Goto partKnown.
* No -> Install with reboot. Goto allow.
* Cancel -> terminate installation. Goto abort.
*/
- {
- int x = session.write_message( IMB( message_text.text( L"dialog_unknown" ), IMB::warning_box, IMB::yes_no_cancel, IMB::default_button_three ) ) ;
+ {
+ int x = session.WriteMessage(IMB(
+ messageText.text(L"dialog_unknown"),
Eric 2015/01/04 19:02:43 And this one.
+ IMB::Box::warning, IMB::ButtonSet::yesNoCancel, IMB::DefaultButton::three
+ )) ;
switch ( x )
{
case IDYES:
- state = part_known ;
+ state = partKnown ;
break ;
case IDNO:
state = allow ;
@@ -280,22 +283,25 @@
session.log( "User cancelled installation" ) ;
break ;
default:
- throw unexpected_return_value_from_message_box() ;
+ throw UnexpectedReturnValueFromMessageBox() ;
}
}
break ;
- case part_known:
+ case partKnown:
/*
* Precondition: interactive session
*
* Ask the user "Would you like the installer to close IE for you?"
* Yes -> Goto automatic
* No -> Goto active
- * Cancel -> Goto not_known
+ * Cancel -> Goto notKnown
*/
{
- int x = session.write_message( IMB( message_text.text( L"dialog_part_known" ), IMB::warning_box, IMB::yes_no_cancel, IMB::default_button_three ) ) ;
+ int x = session.WriteMessage(IMB(
+ messageText.text(L"dialog_part_known"),
+ IMB::Box::warning, IMB::ButtonSet::yesNoCancel, IMB::DefaultButton::three
+ )) ;
switch ( x )
{
case IDYES:
@@ -305,10 +311,10 @@
state = active ;
break ;
case IDCANCEL:
- state = not_known ;
+ state = notKnown ;
break ;
default:
- throw unexpected_return_value_from_message_box() ;
+ throw UnexpectedReturnValueFromMessageBox() ;
}
}
break ;
@@ -321,10 +327,13 @@
* IE is still running ->
* Ask the user to close IE manually
* OK -> re-enter this state
- * Cancel -> Goto not_known
+ * Cancel -> Goto notKnown
*/
{
- int x = session.write_message( IMB( message_text.text( L"dialog_active_retry" ), IMB::warning_box, IMB::ok_cancel, IMB::default_button_one ) ) ;
+ int x = session.WriteMessage(IMB(
+ messageText.text(L"dialog_active_retry"),
+ IMB::Box::warning, IMB::ButtonSet::okCancel, IMB::DefaultButton::one
+ )) ;
switch ( x )
{
case IDOK:
@@ -334,17 +343,17 @@
* If it's not, then the user has closed IE and we're done.
*/
iec.refresh() ;
- if ( ! iec.is_running() )
+ if ( ! iec.IsRunning() )
{
state = success ;
session.log( "User shut down IE manually." ) ;
}
break ;
case IDCANCEL:
- state = not_known ;
+ state = notKnown ;
break ;
default:
- throw unexpected_return_value_from_message_box() ;
+ throw UnexpectedReturnValueFromMessageBox() ;
}
}
break ;
@@ -359,28 +368,31 @@
* Failed && interactive ->
* Ask user if they would like to try again
* Retry -> re-enter this state
- * Cancel -> Goto not_known
+ * Cancel -> Goto notKnown
* Failed && not interactive -> Goto abort
*/
{
- bool IE_was_closed = iec.shut_down() ;
- if ( iec.is_running() )
+ bool ieWasClosed = iec.shutDown() ;
+ if ( iec.IsRunning() )
{
session.log( "Attempt to shut down IE automatically failed." ) ;
if ( interactive )
{
// Assert Interactive session and IE did not shut down.
- int x = session.write_message( IMB( message_text.text( L"dialog_automatic_retry" ), IMB::warning_box, IMB::retry_cancel, IMB::default_button_one ) ) ;
+ int x = session.WriteMessage(IMB(
+ messageText.text(L"dialog_automatic_retry"),
+ IMB::Box::warning, IMB::ButtonSet::retryCancel, IMB::DefaultButton::one
+ )) ;
switch ( x )
{
case IDRETRY:
// Don't change the state. Iterate again.
break ;
case IDCANCEL:
- state = not_known ;
+ state = notKnown ;
break ;
default:
- throw unexpected_return_value_from_message_box() ;
+ throw UnexpectedReturnValueFromMessageBox() ;
}
}
else
@@ -392,7 +404,7 @@
}
else
{
- // Assert IE is not running, so shut_down() succeeded.
+ // Assert IE is not running, so shutDown() succeeded.
state = success ;
session.log( "Automatically shut down IE." ) ;
}
@@ -406,15 +418,15 @@
switch ( state )
{
case success:
- if ( iec.is_running() )
+ if ( iec.IsRunning() )
{
- browser_running = L"1" ;
- browser_closed = L"0" ;
+ browserRunning = L"1" ;
+ browserClosed = L"0" ;
}
else
{
- browser_running = L"0" ;
- browser_closed = L"1" ;
+ browserRunning = L"0" ;
+ browserClosed = L"1" ;
}
return ERROR_SUCCESS ;
break;
@@ -425,34 +437,14 @@
}
catch( std::exception & e )
{
- session.log_noexcept( "terminated by exception: " + std::string( e.what() ) ) ;
+ session.LogNoexcept( "terminated by exception: " + std::string( e.what() ) ) ;
return ERROR_INSTALL_FAILURE ;
}
catch( ... )
{
- session.log_noexcept( "terminated by unknown exception" ) ;
+ session.LogNoexcept( "terminated by unknown exception" ) ;
return ERROR_INSTALL_FAILURE ;
}
// Should be unreachable.
return ERROR_INSTALL_FAILURE ;
}
-
-/*
- * EnumWindows system call: http://msdn.microsoft.com/en-us/library/windows/desktop/ms633497%28v=vs.85%29.aspx
- */
-/**
- *
- * Callback function for EnumWindows.
- */
-BOOL CALLBACK EnumWindowsProc(HWND hwnd, LPARAM lParam)
-{
- return TRUE ;
-}
-
-/**
- * Windows_List
- */
-class Window_List {
-public:
- void enumerate_top_level();
-};

Powered by Google App Engine